486 research outputs found

    Ecografia

    Get PDF

    Evaluation of the severity of chronic hepatitis C with 3-T 1H-MR spectroscopy

    Get PDF
    OBJECTIVE. The purpose of this study was to compare the spectral characteristics of lipids, choline-containing compounds, and glutamine-glutamate complex assessed with H-1-MR spectroscopy with the histologic findings in patients with chronic hepatitis C. SUBJECTS AND METHODS. Nine healthy controls and 30 patients with biopsy-proven hepatitis C virus-related liver disease participated in this prospective study. Degree of fibrosis and histologic activity were scored according to the METAVIR classification. The percentage of involved hepatocytes was used to grade steatosis. Hepatic spectra were obtained with a 3-T spectroscopic system. Tenfold cross-validated stepwise discriminant analysis was performed to classify disease severity on the basis of the spectroscopic findings. RESULTS. There was a strong correlation between H-1-MR spectroscopically measured lipid concentration and the degree of steatosis at histologic examination (r=0.9236, p < 0.0001). This finding enabled clear separation of groups according to degree of histologically determined steatosis. Variation in lipid concentration was consistent with the degree of steatosis (r=0.7265, p < 0.0001) and stage of fibrosis (r=0.8156, p < 0.0001). In univariate analysis, concentrations of both choline-containing compounds and glutamine-glutamate complex had a direct correlation with histologic grade ( p < 0.0001) and degree of steatosis ( p < 0.0001) but not with stage of fibrosis ( p > 0.05). In multivariate analysis, the only factor independently associated with concentrations of choline-containing compounds and glutamine-glutamate complex was histologic grade. In cross-validated discriminant analysis based on choline-containing compound, glutamine-glutamate complex, and lipid resonance, 70% ( 21 of 30) of the histologic grade groups and 73% (22 of 30) of the steatosis groups were correctly classified. CONCLUSION. Hydrogen-1 MR spectroscopy can be an alternative to liver biopsy in the evaluation of steatosis and necroinflammatory activity in liver disease but is not useful for complete evaluation of hepatic fibrosis

    MR breast imaging: A comparative analysis of conventional and parallel imaging acquisition [RM delle mammelle: Confronto tra tecnica convenzionale ed imaging parallelo]

    Get PDF
    Purpose. The objective of this study was to compare conventional breast magnetic resonance imaging (MRI) with breast MRI acquired with the sensitivity-encoding (SENSE) technique on a 1.5-T MRI scanner in the same patient, on the basis of image quality and kinetics analysis. Materials and methods. Thirty-one patients with suspicious mammography and US findings were included in the study. Conventional breast MRI consisted of the following sequences: T1 (matrix, 288x512); T2 (matrix 225x512); short tau inversion recovery (STIR) (matrix 320x224) and dynamic T1 [2D fast-field echo (FFE)] (matrix 256x512; temporal resolution =80 s). The SENSE technique included the following sequences: T1 (matrix 512x512); T2 (matrix 512x512); short-tau inversion recovery (STIR) (matrix 320x224); dynamic T1 (3D FFE) (matrix 512x512, with a temporal resolution ≤70 s). Image quality was graded on a four-point scale, and the mean scores given to each sequence were compared between the two protocols. The relative enhancement rates and the qualitative features of the signal intensity (SI)/time curves were also compared between the two protocols. Results. The readers found 64 contrast-enhanced lesions in 31 patients. Nineteen patients had a total of 27 malignant lesions. In the remaining 12 patients, 37 benign lesions were found. No significant differences between the two protocols were observed with regard to the mean relative enhancement rates and the qualitative features of the SI/time curves. In detail, the mean image quality scores were higher for SENSE imaging (p<0.05). The mean image quality score for the T1 and T2 morphological sequences were comparable. In contrast, the quality scores for the STIR images differed significantly between the two protocols (p<0.001), and a significant difference was also observed when comparing the T1 postcontrast images (p<0.001). Conclusions. Our data suggest that the SENSE imaging protocol applied in our study is superior to conventional imaging with regard to image quality, especially for T1 postcontrast and STIR images. SENSE imaging protocols may provide an alternative to conventional sequences for contrast-enhanced MRI of the breast using 1.5-T MR scanners. © 2008 Springer-Verlag

    Solitary pulmonary nodules: Morphological and metabolic characterisation by FDG-PET-MDCT [Nodulo polmonare solitario: Caratterizzazione morfologico-metabolica mediante imaging integrato TCms/FDG-PET]

    Get PDF
    Purpose. This study was done to analyse the additional morphological and functional information provided by the integration of [18F]-2-fluoro- 2-deoxy-D-glucose positron emission tomography ([18F]-FDG-PET) with contrast-enhanced multidetector computed tomography (MDCT) in the characterisation of indeterminate solitary pulmonary nodules (SPNs). Materials and methods. Fifty-six SPNs, previously classified as indeterminate, were evaluated using a Discovery ST16 PET/CT system (GE Medical Systems) with nonionic iodinated contrast material and [18F]-FDG as a positron emitter. Images were evaluated on a dedicated workstation. Semiquantitative parameters of [18F]-FDG uptake and morphological, volumetric and densitometric parameters before and after contrast administration were analysed. Results were correlated with the histological and follow-up findings. Results. Twenty-six SPNs were malignant and 30 were benign. Malignant lesions at both PET/CT and histology had a mean diameter of 1.8±1.2 cm, a volume doubling time (DT) of 222 days, a mean standardized uptake value (SUV) of 4.7 versus 1.08 in benign lesions and a mean postcontrast enhancement of 44.8 HU as opposed to 4.8 HU in benign nodules. Malignant lesions had a significantly shorter doubling time and significantly greater postcontrast enhancement compared with benign nodules. Based on the SUV and using a cut-off value of >2.5, PET/CT had a sensitivity of 76.9%, specificity of 100%, diagnostic accuracy of 89.2%, positive predictive value (PPV) of 100% and negative predictive value (NPV) of 83.3%. Based on doubling time (cut off <400 days), it had a sensitivity of 76.9%, specificity of 93.3%, accuracy of 85.7%, PPV of 90.9% and NPV of 82.3%. Based on postcontrast enhancement (cut off >15 HU), it had a sensitivity of 92.3%, specificity of 100%, accuracy of 96.4%, PPV of 100% and NPV of 93.7%. Conclusion. PET/CT allows accurate analysis of anatomical/morphological and metabolic/functional correlations of SPN, providing useful data for identifying and locating the disease, for differentiating between malignant and benign nodules and for establishing the aggressiveness and degree of vascularity of pulmonary lesions. Therefore, partly in view of the considerable reduction in time and cost of the single examinations, we believe that PET/CT will gain an increasingly dominant role in the diagnostic and therapeutic approach to lung cancer, especially in the preclinical phase. © 2007 Springer-Verlag

    Liver contrast enhanced ultrasound perfusion imaging in the evaluation of chronic hepatitis C fibrosis: preliminary results

    Get PDF
    We wanted to determine whether liver contrast-enhanced ultrasound (CEUS)–derived peak signal intensity (PSI) and peak signal intensity/time (PIT) predict liver fibrosis in chronic hepatitis C (CHC). Fortynine patients with CHC (METAVIR classification) and 10 control subjects were included in the study. After a bolus of 2.4 mL SonoVue (Bracco Imaging, Milan, Italy) solution was injected into a peripheral vein, the right lobe of the liver containing the right portal vein was scanned in a transverse section. Two-dimensional sonography was performed using the Philips iU22 ultrasound system (Philips Healthcare, Best, the Netherlands). A 1.0–5.0-MHz (C5-1) wideband convex transducer was used, applying the following settings in all cases. Regions of interest were manually drawn over the right liver lobe and over the portal vein (PV). Liver parenchyma PSI (LPpsi) and PIT (LPpit), portal vein PSI (PVpsi) and PIT (PVpit) were automatically calculated. dPSI was defined as the difference between PVpsi and LPpsi. A significant correlation was observed between PAPSI and fibrosis scores. When patients were stratified according to their LPpsi, a significant difference was achieved only between patients with fibrosis score 0–1 vs. 2–3 and 2 vs. 4. Statistically significant differences between all fibrosis scores, except 0 vs. 1 and 3 vs. 4 were observed when dPSI was used to stratify patients. Overall diagnostic accuracy of LPpsi and dPSI measurement for severe fibrosis by area under the receiving operator characteristic curve analysis was, respectively, 0.87 and 0.88.We suggest that liver CEUS perfusion could have the potential to be used as a complementary tool for the evaluation of liver fibrosis. However, further large-scale studies are required to accurately assess its accuracy in the evaluation of liver fibrosis

    Role of PET/CT in the detection of liver metastases from colorectal cancer

    Get PDF
    The aim of this study was to compare the diagnostic accuracy of 2-[fluorine-18] fluoro-2-deoxy-D-glucose positron emission tomography (F-18-FDG-PET) and computed tomography (CT) with PET/CT in the detection of liver metastases during tumour staging in patients suffering from colorectal carcinoma for the purposes of correct surgical planning and follow-up. A total of 467 patients underwent a PET/CT scan using an iodinated contrast medium. We compared images obtained by the single PET scan, the single CT scan and by the fusion of the two procedures (PET/CT). The final diagnosis was obtained by histological examination and/or by the follow-up of all patients, including those who did not undergo surgery or biopsy. The PET scan had 94.05% sensitivity, 91.60% specificity and 93.36% accuracy; the CT scan had 91.07% sensitivity, 95.42% specificity and 92.29% accuracy. The combined procedures (PET/CT) had the following values: sensitivity 97.92%, specificity 97.71% and accuracy 97.86%. This study indicates that PET/CT is very useful in staging and restaging patients suffering from colorectal cancer. It was particularly useful when recurrences could not be visualised either clinically or by imaging despite increasing tumour markers, as it guaranteed an earlier diagnosis. PET/CT not only provides high diagnostic performance in terms of sensitivity and specificity, enabling modification of patient treatment, but it is also a unique, high-profile procedure that can produce cost savings

    Enhancement of lysosomal glycohydrolase activity in human primary B lymphocytes during spontaneous apoptosis.

    Get PDF
    It has been shown that lysosomes are involved in B cell apoptosis but lysosomal glycohydrolases have never been investigated during this event. In this study we determined the enzymatic activities of some lysosomal glycohydrolases in human tonsil B lymphocytes (TBL) undergoing in vitro spontaneous apoptosis. Fluorimetric methods were used to evaluate the activities of β-hexosaminidases, α-mannosidase, β-mannosidase, β-galactosidase, β-glucuronidase and α-fucosidase. Results show that in TBL during spontaneous apoptosis, there is a significant increase in the activity of β-hexosaminidases, α-mannosidase, β-mannosidase and β-galactosidase. Also β-glucuronidase and α-fucosidase activities increase but not in a significant manner. Further studies on β-hexosaminidases revealed that also mRNA expression of the α- and β-subunits, which constitute these enzymes, increases during spontaneous TBL apoptosis. When TBL are protected from apoptosis by the thiol molecule N-acetyl-L-cysteine (NAC), there is no longer any increase in glycohydrolase activities and mRNA expression of β-hexosaminidase α- and β-subunits. This study demonstrates for the first time that the activities and expression of some lysosomal glycohydrolases are enhanced in TBL during spontaneous apoptosis and that these increases are prevented when TBL apoptosis is inhibited

    Vascular anomalies of the celiac trunk and implications in treatment of HCC with TACE. Description of a case and review of the literature

    Get PDF
    Knowledge of the vascular anatomy of the upper abdomen is important in the daily practice of surgeons specialized in the hepatobiliary and pancreatic area, and for general surgeons and radiologists, mainly those involved in interventional radiology. Since anatomical variants of the celiac axis and hepatic arteries are common, an accurate description of vascularization is required before procedures to avoid iatrogenic vascular changes. We reported a case of a young male patient with HBV related cirrhosis, who came to our institution for the treatment of 2 HCC nodules. The preprocedural contrast-enhanced CT examination showed combined variations of celiac trunk, hepatic arteries, gastroduodenal artery, and right inferior phrenic artery. The careful pre- and intraprocedural evaluation of vascularization allowed us to perform transarterial chemoembolization of the 2 nodules without complications. The incidence and developmental and clinical significance of this variation is discussed with a detailed review of the literature. Knowledge of such a case has important clinical significance in abdominal operations or invasive arterial procedures
    • …
    corecore